WSAL23626 – RS232 – 485 – 422 TO POE ETH (B)/en
Erscheinungsbild
Documentation notice: This technical documentation was independently rewritten from an archived supplier source. Check technical details and commands against the product version and manufacturer documentation before use.

Catalog location in the JW Tech Shop:
- WSAL23626 – Rail-Mount Serial Server, RS232/485/422 to RJ45 Ethernet Module, TCP/IP to serial, POE Function Optional: IoT / Communication → Wired Comm / Converter → Ethernet TO UART / RS232 / RS485
- WSAL24759 – Rail-Mount Serial Server, RS232/485/422 to RJ45 Ethernet Module, TCP/IP to serial, POE Function Optional: Other products
Summary
The module is a serial server / IoT gateway for industrial environments. It connects RS232, RS485 or RS422 to an RJ45 Ethernet port and optionally supports PoE power (IEEE 802.3af). Core function: bidirectional transparent transmission between serial and TCP/IP; plus Modbus gateway, MQTT gateway, and JSON conversion.
Related products at JW Tech
- WSAL23626 – Rail-Mount Serial Server, RS232/485/422 to RJ45 Ethernet Module, TCP/IP to serial, POE Function Optional
- WSAL24759 – Rail-Mount Serial Server, RS232/485/422 to RJ45 Ethernet Module, TCP/IP to serial, POE Function Optional
Technical overview
- Interfaces: 1× isolated RS232/485/422 port and 1× RJ45 Ethernet port with 10/100 Mbps auto-negotiation and 2 kV surge protection.
- Power supply: screw terminal DC 6–36 V (outer diameter 5.5 mm, inner diameter 2.1 mm) or PoE over the network port per IEEE 802.3af.
- Serial parameters: baud rates 300–115200 bps (software range 1200–115200), data bits 5–9, parity: none, odd, even, mark, space; no flow-control mode specified.
- Operating modes: TCP server (up to 30 concurrent connections), TCP client (up to 7 destination IPs, can also run as TCP server simultaneously), UDP, and UDP multicast.
- Protocols: ETHERNET, IP, TCP, UDP, HTTP, ARP, ICMP, DHCP, DNS; configuration via PC software (Vircom) or web browser; dynamic IP via DHCP, name resolution via DNS.
- Advanced features: Modbus RTU↔TCP gateway (with storage and non-storage modes), MQTT gateway, JSON-to-Modbus RTU and 645 meter protocol, HTTP POST/GET data delivery, NTP time sync, custom heartbeat/registration packets, password authentication for TCP connections.
- Dimensions: 88.7 × 64.5 × 24.2 mm (L×W×H); operating temperature −40 °C to 85 °C; humidity 5–95 % RH.
- Typical applications: IoT gateway for cloud connectivity, electricity meters and energy-consumption monitoring, remote monitoring and firmware download for PLCs, communication interfaces for access control and security equipment.
Commands and examples – verify before use:
Vircom: Gerät verwalten → Gerät suchen und konfigurieren (selbe Switch-Vernetzung erforderlich)
SSCOM: TCP-Client öffnen, Ziel-IP 192.168.1.200, Port 4196, dann „Öffnen“ klicken
Web-Konfiguration: Standard-IP 192.168.1.200, Port 1111; Computer auf 192.168.1.199 setzen
Factory Reset: Reset-Pin 5 Sekunden gedrückt halten, um Standardparameter wiederherzustellen
Notes and version constraints
- The IP addresses (192.168.1.200, 192.168.1.199) and ports (4196, 1111) in the source are example values from the test section, not necessarily factory defaults – verify they match your own network setup before use.
- The source contains placeholders such as {{{name3}}}, {{{userDefinedInfo}}} and truncated sections (“bounded source middle omitted”), so details on pinout, exact commands, or firmware versions may be missing.
- The parameter block lists “baud rate 300–115200 bps” while the software section states 1200–115200 bps; which range is actually available should be verified on the device.
- PoE function applies only to models whose designation includes “POE”; plain ETH(B) variants without PoE require power via the screw terminal.
- For RS485 short-distance issues with extra zeros or garbled characters: remove the two 120 Ω termination resistors and set the jumper to NC; for multi-device bus topologies, 120 Ω terminators at bus ends are typical – confirm exact placement for your layout.
- The source mentions a DLL development library and cloud remote search but provides no concrete API commands; consult the manufacturer’s documentation for programmatic integration.
Source and revision record
- RS232/485/422 TO POE ETH (B) - Waveshare Wiki
- Source revision: 98321
- Captured: 2026-08-29T08:18:32+00:00
- SHA-256:
a7cbbe242c4908e589158f93907d875a5589b9e0f7e4e3e8065835025e70b8f2