Summary

Concise technical guide for the Waveshare Modbus RTU 8-channel relay module with RS485 bus, V3 protocol, and safety guidelines.

Related products at JW Tech

Technical overview

  • The module provides 8 relay channels over an RS485 interface using the Modbus RTU protocol.
  • Two variants exist: WSAL17658 with a 5 V power supply and WSAL25739 (variant B) with a 7–36 V power supply.
  • From September 2024, the V3 development protocol is used; it is backward compatible with V2 and adds new features.
  • The serial interface uses standard parameters: 9600 baud, 8 data bits, no parity.
  • For computer interfacing, SSCOM can send hex commands with Modbus CRC16 checksum, or Modbus Poll can read/write relay states.
  • Demo environments are described for Raspberry Pi, STM32 (NUCLEO-F103RB), Arduino (UNO PLUS), and PLC (SIMATIC S7-200 SMART).
  • RS485 must not be connected directly to a Raspberry Pi serial port; an RS485 level converter or the corresponding HAT/shield module is required.
  • The relay environmental specification is -15 °C to +70 °C at 40–85 % relative humidity.

Commands and examples – verify before use: 

sudo raspi-config
sudo reboot
enable_uart=1
#dtoverlay=pi3-miniuart-bt
sudo apt-get install unzip
wget https://files.waveshare.com/wiki/Modbus-RTU-Relay/Modbus_RTU_Relay_Code.zip
unzip Modbus_RTU_Relay_Code.zip
cd Modbus_RTU_Relay_Code/Python3
sudo python3 main.py

Notes and version constraints

  • All statements regarding compatibility, electrical values, commands, prices, stock, certifications, warranty, or safety require confirmation by a qualified professional, as they may be version-sensitive.
  • The exact register addresses and function codes of the V3 protocol are only listed as headings in the source; concrete values are missing from the provided text.
  • The 'Development Protocol V3' section contains no complete tables or command examples in the excerpt; these must be supplemented from the original source.
  • Command formats such as 'Control Single Relay' or 'Set Baudrate Command' appear only as topic headings in the source; exact byte sequences are not included here.
  • Power consumption figures (0.18 W standby / 2.9 W active at 5 V) refer to the 5 V variant; no comparable figures are available for the 7–36 V variant.

Source and revision record