Summary

The UART TO ETH (B) is a compact module that forwards TTL UART data bidirectionally and transparently between serial interfaces and Ethernet. It can serve as a serial server, Modbus gateway, or IoT gateway for industrial environments.

Related products at JW Tech

Technical overview

  • Serial specification: baud rates from 300 to 115200 bps, data bits 5–9, selectable parity (none, odd, even, mark, space), hardware flow control supported.
  • Network protocols: supports TCP server, TCP client, UDP, and UDP multicast; up to 30 simultaneous TCP connections in server mode and 7 destination IPs in client mode.
  • Pinout includes 5V/3.3V power, RST (active-low, minimum 100 ns pulse), TXD/RXD (3.3 V TTL), DEF (hold low >1 s to reset to default IP 192.168.1.254), RUN indicator, EN (RS485 transmit enable), RTS/CTS for flow control, and LINK/ACT/LINK2 status indicators.
  • Configuration is done via web browser or the provided DLL development library; DHCP and DNS are supported.
  • Advanced functions include Modbus RTU-to-TCP gateway, MQTT gateway, JSON-to-Modbus/IEC-645 conversion, NTP time synchronization, user-defined heartbeat/registration packets, and HTTP GET/POST for data submission.
  • Operating temperature range is -40 °C to 85 °C; humidity range is 5 % to 95 % relative humidity.
  • Module dimensions are 34 × 23 × 11.5 mm; it features castellated holes with immersion gold for direct PCB integration.

Notes and version constraints

  • The exact default IP after reset (192.168.1.254) applies only to this model; other variants may use different values.
  • PoE connection requires a PoE splitter to separate power and data; connecting directly to a PoE switch without isolation can damage the module.
  • For Modbus operation, function code compatibility with the connected device must be verified; the correct baud rate should be read from the device.
  • Password change via the web interface: after changing, login is possible only with the new password.
  • Some steps depend on the firmware version; consult the latest manufacturer documentation when uncertain.