Summary

The RS485 TO ETH converter enables conversion of RS485 serial data to Ethernet. It does not support Modbus TCP transmission.

Related products at JW Tech

Technical overview

  • The device is a stable, high-speed and low-power converter for connecting RS485 devices to the Ethernet network.
  • Configuration is done via a web page; the device's MAC address can be looked up there.
  • To restore factory settings: after power-on, press and hold the reload button for 5 seconds.
  • For network connection, the device and computer must use the same network address with different node IPs (e.g., device 192.168.0.7, computer 192.168.0.8).
  • By default the device listens on port 1111 for TCP connections.
  • If data transfer fails, check whether the RX indicator blinks – if it doesn't, no data is being received and wiring must be checked.
  • For RS485 wiring: connect T+ to A, T- to B.
  • Common baud rates are 9600 and 115200; parameters must match the connected RS485 device.
  • Firewalls may block TCP connections; check or temporarily disable firewall settings if needed.
  • If the device is unreachable, ping its default IP to verify the device is still active.

Notes and version constraints

  • Modbus TCP is not supported by this model; a different product in the range provides that function.
  • The exact AT commands are not specified in the source data; please consult the corresponding AT command manual.
  • When configuring IP addresses, ensure the device and computer are in the same subnet but have different host IPs.
  • If the web configuration page cannot be opened, check the direct cabling (device directly to computer) and correct IP assignment.
  • When using Modbus functions, a different device must be used since this model does not provide that capability.