<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="de">
	<id>https://wiki.jw-tech.eu/index.php?action=history&amp;feed=atom&amp;title=WSAL23376_%E2%80%93_RS232_TO_RS485_%28B%29%2Fen</id>
	<title>WSAL23376 – RS232 TO RS485 (B)/en - Versionsgeschichte</title>
	<link rel="self" type="application/atom+xml" href="https://wiki.jw-tech.eu/index.php?action=history&amp;feed=atom&amp;title=WSAL23376_%E2%80%93_RS232_TO_RS485_%28B%29%2Fen"/>
	<link rel="alternate" type="text/html" href="https://wiki.jw-tech.eu/index.php?title=WSAL23376_%E2%80%93_RS232_TO_RS485_(B)/en&amp;action=history"/>
	<updated>2026-10-23T23:04:06Z</updated>
	<subtitle>Versionsgeschichte dieser Seite in JW Tech Wiki</subtitle>
	<generator>MediaWiki 1.43.9</generator>
	<entry>
		<id>https://wiki.jw-tech.eu/index.php?title=WSAL23376_%E2%80%93_RS232_TO_RS485_(B)/en&amp;diff=2954&amp;oldid=prev</id>
		<title>JWTechPublisher: Freigegebene technische Dokumentation veröffentlicht; Text-only und noindex</title>
		<link rel="alternate" type="text/html" href="https://wiki.jw-tech.eu/index.php?title=WSAL23376_%E2%80%93_RS232_TO_RS485_(B)/en&amp;diff=2954&amp;oldid=prev"/>
		<updated>2026-09-07T01:38:05Z</updated>

		<summary type="html">&lt;p&gt;Freigegebene technische Dokumentation veröffentlicht; Text-only und noindex&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Neue Seite&lt;/b&gt;&lt;/p&gt;&lt;div&gt;__NOINDEX__&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Documentation notice:&amp;#039;&amp;#039;&amp;#039; This technical documentation was independently rewritten from an archived supplier source. Check technical details and commands against the product version and manufacturer documentation before use.&lt;br /&gt;
&lt;br /&gt;
== Summary ==&lt;br /&gt;
The RS232 TO RS485 (B) is an active, digitally isolated bi-directional serial converter. It converts RS232 signals into balanced differential RS485 signals and supports reliable transmission at 300–115200 bps. The unit features integrated 600 W lightning/surge protection, a switchable 120 Ω termination resistor, and DIN-rail mounting for industrial use.&lt;br /&gt;
&lt;br /&gt;
== Related products at JW Tech ==&lt;br /&gt;
* [https://shop.jw-tech.eu/p/WSAL23376 WSAL23376 – RS232 To RS485 Converter, Active Digital Isolator, Rail-Mount support, 600W Lightningproof &amp;amp;amp;amp; Anti-Surge, Multi-isolation protection]&lt;br /&gt;
* [https://shop.jw-tech.eu/p/WSAL27830 WSAL27830 – RS232 To RS485 Converter, Active Digital Isolator, Rail-Mount support, 600W Lightningproof &amp;amp;amp;amp; Anti-Surge, Multi-isolation protection]&lt;br /&gt;
&lt;br /&gt;
== Technical overview ==&lt;br /&gt;
* Active digital isolation with integrated power-supply and signal isolation; no external power supply needed for the isolated terminal.&lt;br /&gt;
* Supply voltage: 6–36 V DC via screw terminals; reverse-polarity protection included.&lt;br /&gt;
* Reliable communication range: 300–115200 bps; maximum rate can reach 921600 bps, but only the recommended range is considered stable.&lt;br /&gt;
* RS232 side: screw terminals, point-to-point half-duplex, range approx. 15 m.&lt;br /&gt;
* RS485 side: screw terminals, point-to-multipoint (up to 32 nodes; repeater recommended beyond 16 nodes), range approx. 1200 m.&lt;br /&gt;
* Integrated TVS suppresses voltage spikes; additional resettable fuse and protection diodes provide over-current and over-voltage protection.&lt;br /&gt;
* Optional 120 Ω termination resistor on the RS485 side, enabled by a switch; recommended to enable at the start and end points of the bus segment.&lt;br /&gt;
* ABS DIN-rail-mount case, dimensions L×W×H: 91.6 × 23.3 × 58.7 mm; operating temperature −15 °C to +70 °C.&lt;br /&gt;
&lt;br /&gt;
== Notes and version constraints ==&lt;br /&gt;
* RS485 is half-duplex: simultaneous sending and receiving is not possible; observe test sequence.&lt;br /&gt;
* Correct GND wiring depends on the application: in simple scenarios without a shared reference or interference risk, GND may remain unconnected; in complex systems with high signal-integrity requirements, connect GND according to specification.&lt;br /&gt;
* If malfunction occurs: verify supply voltage with a multimeter (6–36 V), check TXD/RXD cross-wiring, connect RS485 A-A/B-B correctly; the 120 Ω resistor is off by default.&lt;br /&gt;
* The module does not support direct Modbus read/write or protocol conversion; it only performs transparent data forwarding at the physical layer.&lt;br /&gt;
* Beyond 16 RS485 nodes, using a repeater is recommended to ensure reliability.&lt;br /&gt;
&lt;br /&gt;
== Source and revision record ==&lt;br /&gt;
* [https://www.waveshare.com/wiki/RS232_TO_RS485_(B) RS232 TO RS485 (B) - Waveshare Wiki]&lt;br /&gt;
* Source revision: 88232&lt;br /&gt;
* Captured: 2026-09-04T02:53:25+00:00&lt;br /&gt;
* SHA-256: &amp;lt;code&amp;gt;2de1fe6abac271de912c6d721b86757f25ec953f038dec2123f17b8485785548&amp;lt;/code&amp;gt;&lt;/div&gt;</summary>
		<author><name>JWTechPublisher</name></author>
	</entry>
</feed>